產品規格參數LaserwavelengthBasemodel:532nm
Rxn4拉曼光譜分析儀 產品信息

產品規格參數

  • Laser wavelength

    Base model: 532 nm, 785 nm, 1000 nm
    Hybrid: 785 nm

  • Spectral coverage

    Base Model:
    150-4350 cm-1 (532 nm)
    150-3425 cm-1 (785 nm)
    200-2400 cm-1 (1000 nm)
    Hybrid: 175-1890 cm-1 (785 nm)

  • Laser wavelength

    Base model: 532 nm, 785 nm, 1000 nm
    Hybrid: 785 nm

  • Spectral coverage

    Base Model:
    150-4350 cm-1 (532 nm)
    150-3425 cm-1 (785 nm)
    200-2400 cm-1 (1000 nm)
    Hybrid: 175-1890 cm-1 (785 nm)

    • 測量原理

      Raman spectroscopy

    • Laser wavelength

      Base model: 532 nm, 785 nm, 1000 nm
      Hybrid: 785 nm

    • Spectral coverage

      Base Model:
      150-4350 cm-1 (532 nm)
      150-3425 cm-1 (785 nm)
      200-2400 cm-1 (1000 nm)
      Hybrid: 175-1890 cm-1 (785 nm)

    • Spectral resolution

      Base model (average):
      5 cm-1 (532 nm)
      4 cm-1 (785 nm)
      5 cm-1 (1000 nm)
      Hybrid:
      4 cm-1 (785 nm) average

    • Channels

      Base model:
      Up to four channels
      Hybrid:
      Up to two channels

    • Temperature

      Base model:
      Operating: 5 to 35 °C (532 nm, 785 nm); 5 to 30 °C (1000 nm)
      Storage: -15 to 50 °C
      Hybrid:
      Operating: 5 to 35 °C
      Storage: -15 to 50 °C
      Enclosure configuration:
      Operating: 5 to 50 °C (all wavelengths)
      Storage: -15 to 50 °C

    • Relative humidity

      20-80% RH, non-condensing

    • Input voltage

      Base model and Hybrid:
      100-240 V, 50-60 Hz, ±10%
      Enclosure configuration:
      115 V ±10%, 60 Hz -OR-
      230 V ±10%, 50/60 Hz

    • Power consumption (W)

      Base model and Hybrid:
      400 (max)
      250 (typical start-up)
      120 (typical running)
      Enclosure configuration:
      1560 (max)
      1560 (typical start-up)
      750 (typical running)

    • Warm up time (minutes)

      Base model and Hybrid:
      120
      Enclosure configuration:
      240

    • Unit dimensions (width x height x depth in mm)

      Base model and Hybrid:
      483 x 267 x 556
      Enclosure configuration:
      1175 x 1480 x 826 (with optional trolley)

    • Weight (kg)

      Base model and Hybrid:
      28.5
      Enclosure configuration:
      185.5 (with optional trolley)

    • Sampling probe compatibility

      Base model and enclosure configuration:
      Raman Rxn-10 (with accessory optics), Rxn-40, Rxn-41, Rxn-45, Rxn-46
      Hybrid:
      Channel 1 - Raman Rxn-20 (with accessory optics)
      Channel 2 - Raman Rxn-10 (with accessory optics), Rxn-40, Rxn-41, Rxn-45, Rxn-46

    • Automation interface

      OPC
      Modbus
      HTTPS
      (contact us for other options)

    • Installation options

      Base model and Hybrid:
      19-inch rack package
      Enclosure configuration:
      NEMA 4X enclosure; wall-mountable, moblile trolley, or fixed stand

    • Hazardous area certifications

      Base model and Hybrid:
      ATEX, CSA, IECEx
      Enclosure configuration:
      Call support for options

    • 測量原理

      Raman spectroscopy

    • Laser wavelength

      Base model: 532 nm, 785 nm, 1000 nm
      Enclosure configuration: 532 nm, 785 nm, 1000 nm
      Hybrid: 785 nm

    • Spectral coverage

      Base Model and Enclosure configuration:
      150-4350 cm-1 (532 nm)
      150-3425 cm-1 (785 nm)
      200-2400 cm-1 (1000 nm)
      Hybrid: 175-1890 cm-1 (785 nm)

    • Spectral resolution

      Base model and Enclosure configuration (average):
      5 cm-1 (532 nm)
      4 cm-1 (785 nm)
      5 cm-1 (1000 nm)
      Hybrid:
      4 cm-1 (785 nm) average

    • Channels

      Base model and Enclosure configuration:
      Up to four channels
      Hybrid:
      Up to two channels

    • Temperature

      Base model:
      Operating: 5 to 35 °C (532 nm, 785 nm); 5 to 30 °C (1000 nm)
      Storage: -15 to 50 °C
      Hybrid:
      Operating: 5 to 35 °C
      Storage: -15 to 50 °C
      Enclosure configuration:
      Operating: 5 to 50 °C (all wavelengths)
      Storage: -15 to 50 °C

    • Relative humidity

      20-80% RH, non-condensing

    • Input voltage

      Base model and Hybrid:
      100-240 V, 50-60 Hz, ±10%
      Enclosure configuration:
      115 V ±10%, 60 Hz -OR-
      230 V ±10%, 50/60 Hz

    • Power consumption (W)

      Base model and Hybrid:
      400 (max)
      250 (typical start-up)
      120 (typical running)
      Enclosure configuration:
      1560 (max)
      1560 (typical start-up)
      750 (typical running)

    • Warm up time (minutes)

      Base model and Hybrid:
      120
      Enclosure configuration:
      240

    • Unit dimensions (width x height x depth in mm)

      Base model and Hybrid:
      483 x 267 x 556
      Enclosure configuration:
      1175 x 1480 x 826 (with optional trolley)

    • Weight (kg)

      Base model and Hybrid:
      28.5
      Enclosure configuration:
      185.5 (with optional trolley)

    • Sampling probe compatibility

      Base model and enclosure configuration:
      Raman Rxn-10 (with accessory optics)
      Hybrid:
      Channel 1 - Raman Rxn-20 (with accessory optics)
      Channel 2 - Raman Rxn-10 (with accessory optics)

    • Automation interface

      OPC
      Modbus
      HTTPS
      (contact us for other options)

    • Installation options

      Base model and Hybrid:
      19-inch rack package
      Enclosure configuration:
      NEMA 4X enclosure; wall-mountable, moblile trolley, or fixed stand

    • Hazardous area certifications

      Base model and Hybrid:
      ATEX, CSA, IECEx
      Enclosure configuration:
      Call support for options

    • 測量原理

      Raman spectroscopy

    • Laser wavelength

      Base model: 532 nm
      Enclosure configuration: 532 nm

    • Spectral coverage

      Base Model and Enclosure configuration:
      150-4350 cm-1 (532 nm)

    • Spectral resolution

      Base model and Enclosure configuration (average):
      5 cm-1 (532 nm)

    • Channels

      Base model and Enclosure configuration:
      Up to four channels

    • Temperature

      Base model:
      Operating: 5 to 35 °C
      Storage: -15 to 50 °C
      Enclosure configuration:
      Operating: 5 to 50 °C (all wavelengths)
      Storage: -15 to 50 °C

    • Relative humidity

      20-80% RH, non-condensing

    • Input voltage

      Base model:
      100-240 V, 50-60 Hz, ±10%
      Enclosure configuration:
      115 V ±10%, 60 Hz -OR-
      230 V ±10%, 50/60 Hz

    • Power consumption (W)

      Base model:
      400 (max)
      250 (typical start-up)
      120 (typical running)
      Enclosure configuration:
      1560 (max)
      1560 (typical start-up)
      750 (typical running)

    • Warm up time (minutes)

      Base model:
      120
      Enclosure configuration:
      240

    • Unit dimensions (width x height x depth in mm)

      Base model:
      483 x 267 x 556
      Enclosure configuration:
      1175 x 1480 x 826 (with optional trolley)

    • Weight (kg)

      Base model:
      28.5
      Enclosure configuration:
      185.5 (with optional trolley)

    • Sampling probe compatibility

      Raman Rxn-30

    • Automation interface

      OPC
      Modbus
      HTTPS
      (contact us for other options)

    • Installation options

      Base model and Hybrid:
      19-inch rack package
      Enclosure configuration:
      NEMA 4X enclosure; wall-mountable, moblile trolley, or fixed stand

    • Hazardous area certifications

      Base model and Hybrid:
      ATEX, CSA, IECEx
      Enclosure configuration:
      Call support for options