技術參數ApplicationCompressorswithindividuallyledoutPTCsensorsFunctionsMotortemperaturestatic
Application | Compressors with individually led out PTC sensors |
Functions | Motor temperature static, Supply voltage |
Supply voltage | AC 120/240V |
Undervoltage limits | 85V (120V-Netz) / 170V (240V-Netz) |
Permitted ambient temperature | -40...+70°C |
Temperature measuring circuits: Type | 3 separate inputs for PTC sensors acc. to DIN 44081, DIN 44082 |
Temperature measuring circuits: R_trip, static | 13kΩ ±3kΩ |
Temperature measuring circuits: R_reset | 3.25kΩ ±0.5kΩ |
Temperature measuring circuits: Max. length connection line | 30m |
Reset delay: Motor temperature static | 2min ±20s |
Reset of reset delay | Activation of the reset input only possible if there is no error current |
Relay: Connection | Refer to wiring diagram Max. 2.5A C300 |
Relay: Mechanical service life | Approx. 1 million switching cycles |
Interface | Diagnose port (DP) |
Protection class acc. To EN 60529 | IP00 |
Connection type | 6.3mm flat plugs |
Housing material | PA glass-fibre-reinforced |
Mounting | Screw mounted |
Dimensions | Refer to dimensions in mm |
Weight | Approx. 200g |
Check base | EN 61000-6-2, EN 61000-6-3 EN 61010-1 Overvoltage category II Pollution level 2 |
Approval | UL File No. E75899 cURus |
Reset delay | 2min ±20s |