污水處理設備 污泥處理設備 水處理過濾器 軟化水設備/除鹽設備 純凈水設備 消毒設備|加藥設備 供水/儲水/集水/排水/輔助 水處理膜 過濾器濾芯 水處理濾料 水處理劑 水處理填料 其它水處理設備
恩德斯豪斯(中國)
產品規格參數測量誤差Volumeflow(standard):±0
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
9 dm3/min to 162 000 m3/h (2.5 gal/min to 100 000 gal/min)
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +160°F)
PN 40, Class 300, 20K
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +160 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
9 dm3/min to 162 000 m3/h (2.5 gal/min to 100 000 gal/min)
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +160°F)
PN 40, Class 300, 20K
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +160 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
電磁
Flowmeter for basic water and wastewater applications with easy-to-use operation concept.
Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss.
Suitable for elementary measurement tasks such as raw water intake.
Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements.
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). International drinking water approvals. Installation length: DVGW/ISO conform.
Optimum usability – operation with devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
System integration with HART, Modbus RS485. Flexible operation with app and optional display.
DN 25 to 2400 (1 to 90")
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +160 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Volume flow, conductivity, mass flow
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
9 dm3/min to 162 000 m3/h (2.5 gal/min to 100 000 gal/min)
PN 40, Class 300, 20K
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +160°F)
-40 to 60°C (-40 to 140°F)
DN 25 to 300 (1 to 12"): AlSi10Mg, coated
DN 350 to 2000 (14 to 78"): Carbon steel with protective varnish
Polycarbonat; AlSi10Mg, coated
Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish according to EN ISO 12944 C5-M/Im1/Im2/Im3
LCD display with touch & auto rotate
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA
HART, MODBUS RS485
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
CSA, GP
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TüV SüD attestation)
CRN, PED
3.1 material
Drinking water approvals: ACS, KTW/W270, NSF 61, WRAS BS 6920